PLANNING
COMMISSION RECOMMENDATION:
Planning Commission recommended that the Layout Plat be approved
with the following stipulations:
Engineering
Division Recommendations:
1. Upon submittal of a Preliminary Plat, a drainage plan shall be
submitted for review and approval. In addition, the plat document
shall be revised to provide drainage easements as needed;
2. Upon submittal of the Preliminary Plat, water plans prepared by
a Registered Professional Engineer showing the extension of water
mains shall be submitted for review and approval;
3. Upon submittal of a Preliminary Plat, sewer plans prepared by a
Registered Professional Engineer showing the extension of sanitary
sewer mains and service lines shall be submitted for review and approval;
4. Upon submittal of a Preliminary Plat, road construction plans for
Thrush Drive shall be submitted for review and approval. In particular,
Thrush Drive shall be constructed with a minimum 24 foot wide paved
surface, curb, gutter, sidewalk, street light conduit, water and sewer
or a Variance to the Subdivision Regulations shall be obtained;
5. Upon submittal of a Preliminary Plat, road construction plans for
West Boulevard North shall be submitted for review and approval. In
particular, West Boulevard North shall be constructed with a 27 foot
wide paved surface, curb, gutter sidewalk, street light conduit, water
and sewer or a Variance to the Subdivision Regulations shall be obtained;
6. Upon submittal of a Preliminary Plat, road construction plans for
Oriole Drive shall be submitted for review and approval. In particular,
Oriole Drive shall be constructed with a 24 foot wide paved surface,
curb, gutter, sidewalk, street light conduit, water and sewer or a
Variance to the Subdivision Regulations shall be obtained;
7. Prior to the vacation of the southern 135 feet of Oriole Drive,
the applicant shall submit a site plan identifying the location of
all existing utilities. In addition, the plat document shall be revised
to show that portion of Oriole Drive proposed to be vacated as a utility
easement. The applicant shall also enter into an agreement assuming
responsibility for any replacement of surface improvement(s) for the
same portion of Oriole Drive to be vacated. In addition, right-of-way
shall be provided at the southern terminus of the street for the construction
of a cul-de-sac bulb with a minimum 96 foot diameter right-of-way
and a 76 foot diameter paved surface;
8. Upon submittal of a Preliminary Plat, the plat document shall be
revised to show a non-access easement along West Boulevard North;
9. Prior to Preliminary Plat approval by the City Council, a subdivision
estimate form shall be submitted for review and approval;
Fire
Department Recommendations:
10. Upon submittal of the Preliminary Plat, a fire hydrant design
plan showing the location of fire hydrants and water lines, including
the size of the proposed water lines, shall be submitted for review
and approval; and,
Urban
Planning Division Recommendations:
11. Prior to Final Plat approval, surety for any required subdivision
improvements that have not been completed shall be posted and the
subdivision inspection fees shall be paid.
VOTE: (7 to 0 with Brannan,
Henning, Nash, Prairie Chicken, Schmidt, Stone and Wevik voting yes
and none voting no)
|